Request a Quote 0

BTT-60PM

Current Transformer

AvailabilityPartner stock
Availability
Partner stock
Condition
New
Warranty
6 Months
Price on request

Price and lead time are confirmed before payment.

Description

BTT-60PM current transformer block

BTT-60PM is an aviation current-transformer block used with the GT60PCh6A three-phase AC generator. It supplies measurement signals to the regulation, protection and parallel-operation circuits of a 60 kVA generator channel. The block is therefore selected as part of a defined electrical system, not as a generic standalone transformer.

The suffix PM is part of the designation and must be preserved. BTT units with a similar current rating, housing or connector arrangement must not be treated as automatic substitutes.

Full descriptionCollapse description

BTT-60PM protection and regulation functions

The documented BTT-60PM construction includes four toroidal current transformers, three U-shaped transformers assembled in unit U1 and three diodes in unit U2. Three toroidal transformers participate in reactive-load distribution. The fourth supports active-load distribution and protection against current unbalance during parallel generator operation.

The three U-shaped transformers work with matching transformers installed at the generator. This differential arrangement detects current differences associated with a fault in the generator or feeder. In the documented channel, the BZU-376SP protection unit receives the resulting signal and commands emergency generator disconnection.

BTT-60PM channel parameters

The associated GT60PCh6A generator channel is rated at 60 kVA, 208/120 V, 400 Hz and approximately 166.7 A phase current. These values describe the generator channel in which the BTT-60PM operates; they are not independent output ratings of the transformer block. Exact transformation ratios, winding data and acceptance limits must be taken from the product passport.

Correct phase sequence, conductor routing and installation orientation are essential for differential protection and load sharing. Functional testing requires the approved test procedure and calibrated equipment.

BTT-60PM aircraft and connected equipment

BTT-60PM is documented in the electrical power system of the Ilyushin Il-76. Exact applicability depends on aircraft series and electrical-system configuration. Related system equipment may include the BZU-376SP-4S, but a system association does not establish interchangeability or a complete delivery set.

Ordering and identification of BTT-60PM

For an accurate enquiry, state BTT-60PM exactly, the quantity, required condition and documentation. A data-plate photograph and the generator designation help confirm the correct execution. Related BTT products are listed in Power Transducers. Availability, test status, completeness and accompanying documents are confirmed for the offered unit.

Technical details

Product Type
Aviation current transformer block
Part Number
BTT-60PM
Alternative Designations
BTT-60PM; BTT60PM; BTT 60PM; БТТ-60ПМ
Primary Function
Current sensing for generator protection, regulation and load-sharing circuits
Associated Generator
GT60PCh6A
All specificationsCollapse specifications
Generator Power Class
60 kVA
Generator-Channel Voltage
208/120 V AC
Operating Frequency
400 Hz
Associated Phase Current
Approximately 166.7 A at rated generator load
Construction
Four toroidal current transformers; U1 assembly with three U-shaped transformers; U2 assembly with three diodes
Protection Principle
Differential comparison with current transformers installed at the generator
Protected Circuit
Generator and feeder
Parallel-Operation Functions
Active- and reactive-load distribution and current-unbalance protection
Associated Protection Unit
BZU-376SP family; exact execution must match the aircraft system
Documented Aircraft Context
Ilyushin Il-76; confirm aircraft series and electrical-system configuration
Installation Requirements
Observe phase sequence, conductor routing and the orientation specified by the aircraft wiring documentation
Compatibility
Confirm the full suffix, generator type, connectors and protection/regulation circuit
Documentation
Product passport, generator-channel schematic and approved electrical-equipment manual

Payment & delivery

Orders ship from our hub in Dubai. Partner stock is first transferred to Dubai, then shipped to you.

Dubai stock: 100% before dispatch. Partner stock (Remote stock) and Pre-order: 50% advance payment to start the order and 50% before shipment from Dubai to you.

Availability, lead time, delivery cost and payment terms are confirmed for your order before payment.

Payment & delivery terms

Questions about this part?

Send your requirements — we’ll clarify the details for your order.

Share this part

BTT-60PM