Request a Quote 0
Back to catalog

OK8-00-2

check valve

AvailabilityPre-order
Availability
Pre-order
Condition
New
Warranty
6 Months
Price on request

Price and lead time are confirmed before payment.

Description

Purpose of OK8-00-2 in an onboard system

OK8-00-2 is a Liquid-system check valve that allows the working medium to pass only in the direction marked on the body and automatically blocks reverse flow. Its published working medium is alcohol-water mixture. The unit is a functional element of a defined line, not an independent pressure source. Correct selection depends on more than the body marking: connection geometry, working medium, flow direction, pressure class and the exact execution must all agree with the installation. This page was rebuilt from the specialist Uralprom catalogue and cross-checked against available aviation documentation; specifications were not borrowed from visually similar products. This check is particularly important for legacy designations that may appear with a space, a hyphen or no separator in paper passports, stock databases and export lists. Search forms help identify the item, but they do not change its physical execution.

Full descriptionCollapse description

How the OK8-00-2 unit operates

Differential pressure from the permitted direction overcomes the closing element and opens the passage. Reverse differential pressure drives the element onto its seat and isolates the line. The action is automatic, with no electrical command or separate actuator. The valve does not create pressure and does not regulate normal flow; its defined task is to prevent unwanted movement of the medium in the opposite direction. Reliable operation depends on a clean working medium, serviceable seating surfaces and seals, undamaged threads and correct body orientation. If a connected actuator does not hold position or line pressure falls, maintenance personnel normally inspect not only OK8-00-2, but also the pump, filter, pipelines, fittings, power cylinder and adjacent valves in the same circuit.

Published operating data and connections

Published catalogue data gives a nominal pressure of 1.8 MPa / 18 kgf/cm², a nominal flow capacity of 10 L/min, hydraulic resistance of not more than 0.12 MPa / 1.2 kgf/cm² at nominal flow, an operating temperature range of −60 °C to +60 °C, and the following opening parameter: 0.1 MPa / 1.0 kgf/cm². Mass: not more than 0.15 kg. not stated in the reviewed catalogue These values help distinguish the unit from similar catalogue positions and verify the mounting location. Exact installation geometry must be confirmed from the product passport. Before installation, the figures should be checked against the product passport, current technical specification and documentation for the particular aircraft. If the supplied unit or its passport records a different execution, the documentation accompanying that unit takes precedence.

Installing OK8-00-2 and confirming aircraft applicability

Installation area: Compatible liquid-service line. No exact aircraft or helicopter type for this execution was independently confirmed in the reviewed public documentation. Applicability is therefore not inferred from appearance or from a neighbouring family designation; it must be established from the IPC, maintenance manual, system diagram or product passport. Routine maintenance normally includes checking the marking, flow direction, connection tightness, body condition and contamination. Selection by diameter or photograph alone is unsafe because a similar body may be produced for another medium, thread, flow capacity or setting. Pumps, cylinders and distributors connected in the same circuit are associated components, but they perform different tasks and must not be presented as interchangeable with this unit. Before installation, the unit should be examined for corrosion, damaged threads and evidence of unsuitable storage; after connection, the approved leakage and functional checks should be completed. Test pressure, preservation method and depreservation procedure cannot be assigned from a general family description and must come from the passport or approved repair documentation. If the nameplate and accompanying documents disagree, installation should stop until the execution is clarified.

Designations, documents and related products

The primary English catalogue designation is OK8-00-2. Procurement lists, export records and Cyrillic documentation may also use: OK 8-00-2; OK-8-00-2; ОК8-00-2; ОК 8-00-2. These forms are included to identify one product, not to create separate items. An enquiry should state the complete marking, system type, working medium, mounting position, required condition, delivery set and whether a passport or test record is needed. The control valves and hydraulic units category also contains related positions: OK 4A, OK 6A, OK 8A, 5653T-01. They belong to the same commercial and functional group, but an internal link does not establish compatibility or interchangeability. The final selection must follow the illustrated parts catalogue and approved aircraft documentation. Serial number, production date and actual delivery set are confirmed separately for the specific supplied unit.

Technical details

Product Type
Liquid-system check valve
Designation
OK8-00-2
Russian Designation
ОК8-00-2
Alternative Designations
OK 8-00-2; OK-8-00-2; ОК8-00-2; ОК 8-00-2
Function
Passing the working medium in the permitted direction and blocking reverse flow
All specificationsCollapse specifications
Working Medium
alcohol-water mixture
Nominal Pressure
1.8 MPa / 18 kgf/cm²
Nominal Flow Capacity
10 L/min
Hydraulic Resistance
not more than 0.12 MPa / 1.2 kgf/cm² at nominal flow
Operating Temperature
−60 °C to +60 °C
Opening Parameter / Thermal Relief
0.1 MPa / 1.0 kgf/cm²
Connection Data
not stated in the reviewed catalogue
Mass
not more than 0.15 kg
Aircraft Type
Not confirmed in the reviewed public documentation
System / Installation Area
Compatible liquid-service line
Nearest Associated Components
Pump, filter, pipeline, distributor and power cylinder in the applicable circuit; exact Part Numbers must be checked in aircraft documentation
Interchangeability
Not established; related positions are not automatic substitutes
Technical Documentation
Product passport, technical specification, system diagram and illustrated parts catalogue when available
Technical Data Source
Specialist Uralprom catalogue; ambiguous rows are identified and require passport verification

Payment & delivery

Orders ship from our hub in Dubai. Partner stock is first transferred to Dubai, then shipped to you.

Dubai stock: 100% before dispatch. Partner stock (Remote stock) and Pre-order: 50% advance payment to start the order and 50% before shipment from Dubai to you.

Availability, lead time, delivery cost and payment terms are confirmed for your order before payment.

Payment & delivery terms

Questions about this part?

Send your requirements — we’ll clarify the details for your order.

Share this part