Description

AZR-2: 2 A DC network protection circuit breaker

AZR-2 is the 2 A execution of the AZR single-pole circuit-breaker family for DC networks up to 30 V. The original Cyrillic designation is АЗР-2. It automatically disconnects a consumer during overload or short circuit and can also provide manual switching in the specified circuit.

Full descriptionCollapse description

Construction

AZR uses a dust- and splash-protected metal housing, lever control, two electrical terminals and a free-trip connection between control and contact mechanisms. Holding the lever in ON does not prevent automatic operation. The family is designed for ordinary panel illumination; K-suffix versions use a white-painted handle end for red-lit panels.

Confirm the 2 A marking, 30 V class and complete designation on delivery. Related Related versions: AZK3-35 and AZK3-40.

Operating data

The nominal network voltage is 27 V DC ±10%. Maximum voltage drop between moving- and fixed-contact buses, excluding the bimetal circuit at rated current, is 180 mV. The operating range is −60 to +60 °C, duty is continuous and endurance is 10,000 make-break cycles at rated resistive load.

Mounting uses two screws. Protection is IP30 for the enclosure and IP00 at the terminals; climatic categories are UHL3 and T3. These family data do not replace current-specific trip calibration, terminal torque or the product passport. Receiving inspection should record the marking, lever action, terminal condition and match to the approved feeder schedule before installation.

Inspection and inquiry

Inspect the case, lever, cover fasteners, nameplate, insulating base and terminals for cracks, overheating, corrosion, looseness or unspecified repair. Verify rated current, network voltage, conductor size and mounting spacing before installation. Wikipedia provides general context on circuit breakers. Browse Aviamisto’s Circuit Breakers category. State AZR-2 / АЗР-2, quantity and documentation in the inquiry.

Technical details

Product Type
Single-pole DC circuit breaker
Primary Designation
AZR-2
Original Cyrillic Designation
АЗР-2
Family
AZR
Rated Current
2 A
All specificationsCollapse specifications
Number of Protected Poles
1
Current Type
DC
Maximum Network Voltage
30 V DC
Nominal Supply Voltage
27 V DC ±10%
Protection Function
Overload and short-circuit disconnection
Trip Mechanism
Free-trip
Manual Function
Lever switching
Housing
Dust- and splash-protected metal enclosure
Maximum Contact-Bus Voltage Drop
180 mV
Voltage-Drop Condition
At rated current, excluding bimetal circuit
Operating Temperature
−60 to +60 °C
Duty
Continuous
Rated-Load Endurance
10,000 make-break cycles
Endurance Load Type
Resistive
Mounting
Two screws
Enclosure Protection
IP30
Terminal Protection
IP00
Climatic Category 1
UHL3
Climatic Category 2
T3
Terminal Count
2
Panel Illumination
Ordinary lighting for non-K execution
Alternative Designations
AZR 2; AZR2; АЗР 2; АЗР2

Payment & delivery

Orders ship from our hub in Dubai. Partner stock is first transferred to Dubai, then shipped to you.

Dubai stock: 100% before dispatch. Partner stock (Remote stock) and Pre-order: 50% advance payment to start the order and 50% before shipment from Dubai to you.

Availability, lead time, delivery cost and payment terms are confirmed for your order before payment.

Payment & delivery terms

Questions about this part?

Send your requirements — we’ll clarify the details for your order.

Share this part

AZR-2