APD-58A Engine Start Control Unit for Mi-8 Helicopters | Aviamisto
Request a Quote 0

APD-58A

Start Control Unit

AvailabilityPre-order
Availability
Pre-order
Condition
New
Warranty
6 Months
Price on request

Price and lead time are confirmed before payment.

Description

APD-58A System Overview

The APD-58A is an aircraft engine start automatic control unit designed for automated control of gas turbine engine start processes within onboard systems of helicopters and aircraft. The unit functions as a programmed control device integrated into the engine starting system architecture.

Full descriptionCollapse description

APD-58A Control Function

The device manages the sequence of activation of engine start system components, including starter operation, ignition systems, and fuel supply, ensuring execution of the start cycle according to a predefined timing program and automatic shutdown upon reaching required parameters or timeout conditions.

APD-58A Aircraft Application

The unit is commonly used on helicopters of the Mi-8 family and on certain aircraft types, where it supports automated start of main engines or auxiliary power units within onboard systems.

APD-58A System Integration

The control unit operates in conjunction with onboard engine and electrical systems, controlling external contactors, ignition units, and fuel valves through programmed time sequences corresponding to start, cold rotation, and false start modes. The product is also known under alternative designations APD-58A and АПД-58А.

Technical details

Product Type
Engine start automatic control unit
Function
Automatic control of gas turbine engine start sequence
Application / Where Used
Aircraft engine and APU start systems
System / Installation Area
Engine start control system
Compatible Aircraft / Equipment
Mi-8 (Mi-8T, Mi-8MT) and similar aircraft
All specificationsCollapse specifications
Compatible Engines
TV2-117; TV3-117
Operating Voltage
27 V DC
Current Consumption
Variable depending on load (up to several amperes during operation)
Controlled Circuits
Starter contactors; ignition coils; fuel solenoid valves; signaling circuits
Operating Modes
Start; Cold Rotation; False Start
Cycle Duration
Approximately 50–60 s
Control Sequence
Starter activation; ignition activation; fuel supply; acceleration; automatic shutdown
Start Termination
Automatic shutdown if required engine speed not reached within defined time
Cold Rotation Mode
Starter operation without fuel and ignition
False Start Mode
System check without full engine start (depending on configuration)
Operating Temperature Range
−60 to +60 °C
Mounting Type
Panel or block installation
Weight
Approximately 2.5–3 kg
Construction Type
Electromechanical or relay-based programmed unit
Technical Documentation
Product passport and operational documentation

Payment & delivery

Orders ship from our hub in Dubai. Partner stock is first transferred to Dubai, then shipped to you.

Dubai stock: 100% before dispatch. Partner stock (Remote stock) and Pre-order: 50% advance payment to start the order and 50% before shipment from Dubai to you.

Availability, lead time, delivery cost and payment terms are confirmed for your order before payment.

Payment & delivery terms

Questions about this part?

Send your requirements — we’ll clarify the details for your order.

Share this part

APD-58A