Request a Quote 0
Back to catalog

P-104

Stagnation Temperature Sensor

AvailabilityPre-order
Availability
Pre-order
Condition
New
Warranty
6 Months
Price on request

Price and lead time are confirmed before payment.

Description

P-104 Stagnation Temperature Sensor

P-104 is an aviation stagnation temperature sensor identified by its complete execution marking. Aircraft air-data and engine documentation identifies P-104 as a receiver for measuring stagnation temperature in an airflow. Existing exact-card data records a measurement range of −60 to +300 °C, two independent electrical signals and mass not exceeding 0.25 kg. The designation must be treated as the primary ordering reference because products from the same family can differ in range, electrical interface, calibration, connector, mounting arrangement or system role. External resemblance is not evidence of interchangeability. Selection should be made from the product passport, the aircraft illustrated parts catalogue and the approved maintenance documentation for the exact installation.

Full descriptionCollapse description

Operating function and signal path

The exposed thermal element senses the temperature reached when the local airflow is brought toward rest and supplies resistance-based signals to compatible air-data or engine-control equipment. The unit is a sensing element within a larger aircraft circuit; it is not a complete indicator, controller or protective system by itself. Its output is interpreted by compatible receiving equipment, so supply characteristics, polarity or phase, connector pinout, load and calibration must match the documented configuration. Probe position, airflow, self-heating current, resistance characteristic and wiring affect accuracy and must follow the exact installation documentation. A general explanation of the underlying measurement class is available in this technical reference. That general reference explains the principle only and does not replace product-specific documentation.

Aircraft and equipment application

P-104 is used in aircraft air-data and engine regulation contexts; the exact aircraft, engine and channel must be confirmed from the parts catalogue. Where an aircraft or engine family is named, the statement identifies a documented installation context rather than universal applicability to every modification. The exact equipment set, production series and installed connector must be checked before ordering. Related products in the aviation sensors category are provided for catalogue navigation. The P-2TR card is another same-category reference, but the link does not state that the two units are interchangeable or perform the same function.

Installation and maintenance checks

Before installation, technicians should compare the nameplate, suffix, connector, mounting faces and available acceptance record with the approved requirement. The housing, pressure ports or mechanical input, electrical contacts and sealing features should be inspected without altering calibration. Wiring continuity, insulation and output checks must follow the passport limits for this execution. Do not apply a supply voltage, pressure, acceleration, rotation or test signal taken from a neighbouring model. Storage condition and preservation date should also be reviewed when the unit has remained in stock for an extended period.

After installation, functional testing must be performed as part of the complete aircraft circuit, using approved test equipment and the limits defined by the maintenance manual. A correct bench response alone does not prove that the installation wiring, pneumatic lines, mechanical linkage or receiving unit is serviceable. Any discrepancy should be traced without adjusting sealed elements unless the repair documentation expressly authorises that procedure. The maintenance record should identify the fitted designation and serial number so that later troubleshooting does not confuse adjacent family executions.

Ordering P-104

An enquiry should state P-104, the required condition, quantity, aircraft or equipment context and the documentation needed with delivery. If the installed marking is incomplete, provide a clear photograph of the label, connector and mounting arrangement together with the relevant catalogue reference. Aviamisto can compare these identifiers before supply, but final installation approval remains with the operator or maintenance organisation. Technical Details below separates confirmed data from values that still require passport verification. Same-category cross-sells are navigation aids only; they must never be interpreted as approved replacements.

For a traceable quotation, also state whether a new-production unit, preserved stock item or another documented condition is acceptable. Requested acceptance documents, test records and packing requirements should be agreed before order placement.

Technical details

Product Type
Stagnation temperature receiver / sensor
Original Designation
П-104
Documented Temperature Range
−60 to +300 °C
Independent Signals
Two
Mass
Not more than 0.25 kg
All specificationsCollapse specifications
Static Characteristic
Existing card cites GOST 6651-78; confirm exact execution passport
Measuring Current / Insulation
Confirm from legible passport; former OCR values are not repeated
Primary Designation
P-104
Original Cyrillic Designation
П-104
Alternative Designations
P-104; P104; P 104; П-104; П104; П 104; 6Yu2.821.073; 6Ю2.821.073
Manufacturer
Not confirmed for the offered unit
Aircraft / Equipment Application
According to the exact aircraft, engine or equipment documentation stated above
Installation Position
Confirm from the illustrated parts catalogue and maintenance manual
Connector / Pinout
Confirm from the passport for the exact execution
Interchangeability
Not established by family name or external appearance
Documentation
Product passport and applicable installation / maintenance documentation
Ordering Check
Full marking, suffix, connector, required condition and documents
Acceptance Control
Compare marking, interfaces and test record with the approved requirement before installation
Data Rule
Unlisted values must be confirmed from the exact passport and not copied from another execution
Related Products
Same-category links are navigation only and do not state interchangeability

Payment & delivery

Orders ship from our hub in Dubai. Partner stock is first transferred to Dubai, then shipped to you.

Dubai stock: 100% before dispatch. Partner stock (Remote stock) and Pre-order: 50% advance payment to start the order and 50% before shipment from Dubai to you.

Availability, lead time, delivery cost and payment terms are confirmed for your order before payment.

Payment & delivery terms

Questions about this part?

Send your requirements — we’ll clarify the details for your order.

Share this part