IDT-8
Heat-Resistant Pressure Sensor
Description
IDT-8 Heat-Resistant Pressure Sensor
IDT-8 is an aviation heat-resistant inductive pressure sensor identified by its complete execution marking. Published aviation listings identify IDT-8 as a heat-resistant pressure sensor; the T suffix distinguishes it from standard-temperature ID executions. Existing exact-card data records 36 V, 400 Hz excitation, 0.15 A current, operation from −60 to +220 °C and 475 g mass. The designation must be treated as the primary ordering reference because products from the same family can differ in range, electrical interface, calibration, connector, mounting arrangement or system role. External resemblance is not evidence of interchangeability. Selection should be made from the product passport, the aircraft illustrated parts catalogue and the approved maintenance documentation for the exact installation.
Full descriptionCollapse description
Operating function and signal path
The pressure element converts applied pressure into an inductive signal for a remote indicator while retaining operation in a high-temperature installation zone. The unit is a sensing element within a larger aircraft circuit; it is not a complete indicator, controller or protective system by itself. Its output is interpreted by compatible receiving equipment, so supply characteristics, polarity or phase, connector pinout, load and calibration must match the documented configuration. Pressure range, approved medium, thermal routing, connector and associated indicator are specific to IDT-8 and require the passport. A general explanation of the underlying measurement class is available in this technical reference. That general reference explains the principle only and does not replace product-specific documentation.
Aircraft and equipment application
IDT-8 is intended for pressure measurement where elevated ambient or medium temperature requires a heat-resistant execution; exact aircraft and engine position require documentation. Where an aircraft or engine family is named, the statement identifies a documented installation context rather than universal applicability to every modification. The exact equipment set, production series and installed connector must be checked before ordering. Related products in the aviation sensors category are provided for catalogue navigation. The ID-100 card is another same-category reference, but the link does not state that the two units are interchangeable or perform the same function.
Installation and maintenance checks
Before installation, technicians should compare the nameplate, suffix, connector, mounting faces and available acceptance record with the approved requirement. The housing, pressure ports or mechanical input, electrical contacts and sealing features should be inspected without altering calibration. Wiring continuity, insulation and output checks must follow the passport limits for this execution. Do not apply a supply voltage, pressure, acceleration, rotation or test signal taken from a neighbouring model. Storage condition and preservation date should also be reviewed when the unit has remained in stock for an extended period.
After installation, functional testing must be performed as part of the complete aircraft circuit, using approved test equipment and the limits defined by the maintenance manual. A correct bench response alone does not prove that the installation wiring, pneumatic lines, mechanical linkage or receiving unit is serviceable. Any discrepancy should be traced without adjusting sealed elements unless the repair documentation expressly authorises that procedure. The maintenance record should identify the fitted designation and serial number so that later troubleshooting does not confuse adjacent family executions.
Ordering IDT-8
An enquiry should state IDT-8, the required condition, quantity, aircraft or equipment context and the documentation needed with delivery. If the installed marking is incomplete, provide a clear photograph of the label, connector and mounting arrangement together with the relevant catalogue reference. Aviamisto can compare these identifiers before supply, but final installation approval remains with the operator or maintenance organisation. Technical Details below separates confirmed data from values that still require passport verification. Same-category cross-sells are navigation aids only; they must never be interpreted as approved replacements.
For a traceable quotation, also state whether a new-production unit, preserved stock item or another documented condition is acceptable. Requested acceptance documents, test records and packing requirements should be agreed before order placement.
Technical details
- Product Type
- Heat-resistant inductive pressure sensor
- Original Designation
- ИДТ-8
- Supply Voltage
- 36 V ±6%
- Supply Frequency
- 400 Hz ±2%
- Current
- 0.15 A
All specificationsCollapse specifications
- Operating Temperature
- −60 to +220 °C
- Mass
- 475 g
- Exact Pressure Range / Medium
- Confirm from the IDT-8 passport
- Primary Designation
- IDT-8
- Original Cyrillic Designation
- ИДТ-8
- Alternative Designations
- IDT-8; IDT 8; IDT8; ИДТ-8; ИДТ 8; ИДТ8
- Manufacturer
- Not confirmed for the offered unit
- Aircraft / Equipment Application
- According to the exact aircraft, engine or equipment documentation stated above
- Installation Position
- Confirm from the illustrated parts catalogue and maintenance manual
- Connector / Pinout
- Confirm from the passport for the exact execution
- Interchangeability
- Not established by family name or external appearance
- Documentation
- Product passport and applicable installation / maintenance documentation
- Ordering Check
- Full marking, suffix, connector, required condition and documents
- Acceptance Control
- Compare marking, interfaces and test record with the approved requirement before installation
- Data Rule
- Unlisted values must be confirmed from the exact passport and not copied from another execution
- Related Products
- Same-category links are navigation only and do not state interchangeability
Payment & delivery
Orders ship from our hub in Dubai. Partner stock is first transferred to Dubai, then shipped to you.
Dubai stock: 100% before dispatch. Partner stock (Remote stock) and Pre-order: 50% advance payment to start the order and 50% before shipment from Dubai to you.
Availability, lead time, delivery cost and payment terms are confirmed for your order before payment.
Payment & delivery terms