DDC-1
Oxygen Consumption Sensor
Description
DDC-1 Oxygen Consumption Sensor
DDC-1 is an aviation oxygen-consumption monitoring sensor identified by its complete execution marking. Existing aviation product data states that DDC-1 monitors the presence of oxygen consumption in a crew life-support system. The sensor works with the IKZH-1 indicator; unrelated 230 V motion-sensor values formerly present in Technical Details were rejected as copied data. The designation must be treated as the primary ordering reference because products from the same family can differ in range, electrical interface, calibration, connector, mounting arrangement or system role. External resemblance is not evidence of interchangeability. Selection should be made from the product passport, the aircraft illustrated parts catalogue and the approved maintenance documentation for the exact installation.
Full descriptionCollapse description
Operating function and signal path
The unit provides a status related to oxygen flow or consumption for the compatible life-support indication circuit. The unit is a sensing element within a larger aircraft circuit; it is not a complete indicator, controller or protective system by itself. Its output is interpreted by compatible receiving equipment, so supply characteristics, polarity or phase, connector pinout, load and calibration must match the documented configuration. Exact sensing method, threshold and connector data require the DDC-1 passport. A general explanation of the underlying measurement class is available in this technical reference. That general reference explains the principle only and does not replace product-specific documentation.
Aircraft and equipment application
DDC-1 belongs to an aircraft oxygen / crew life-support system used with IKZH-1; the exact platform is not confirmed by the available source. Where an aircraft or engine family is named, the statement identifies a documented installation context rather than universal applicability to every modification. The exact equipment set, production series and installed connector must be checked before ordering. Related products in the aviation sensors category are provided for catalogue navigation. The DVGM card is another same-category reference, but the link does not state that the two units are interchangeable or perform the same function.
Installation and maintenance checks
Before installation, technicians should compare the nameplate, suffix, connector, mounting faces and available acceptance record with the approved requirement. The housing, pressure ports or mechanical input, electrical contacts and sealing features should be inspected without altering calibration. Wiring continuity, insulation and output checks must follow the passport limits for this execution. Do not apply a supply voltage, pressure, acceleration, rotation or test signal taken from a neighbouring model. Storage condition and preservation date should also be reviewed when the unit has remained in stock for an extended period.
After installation, functional testing must be performed as part of the complete aircraft circuit, using approved test equipment and the limits defined by the maintenance manual. A correct bench response alone does not prove that the installation wiring, pneumatic lines, mechanical linkage or receiving unit is serviceable. Any discrepancy should be traced without adjusting sealed elements unless the repair documentation expressly authorises that procedure. The maintenance record should identify the fitted designation and serial number so that later troubleshooting does not confuse adjacent family executions.
Ordering DDC-1
An enquiry should state DDC-1, the required condition, quantity, aircraft or equipment context and the documentation needed with delivery. If the installed marking is incomplete, provide a clear photograph of the label, connector and mounting arrangement together with the relevant catalogue reference. Aviamisto can compare these identifiers before supply, but final installation approval remains with the operator or maintenance organisation. Technical Details below separates confirmed data from values that still require passport verification. Same-category cross-sells are navigation aids only; they must never be interpreted as approved replacements.
For a traceable quotation, also state whether a new-production unit, preserved stock item or another documented condition is acceptable. Requested acceptance documents, test records and packing requirements should be agreed before order placement.
Technical details
- Product Type
- Oxygen-consumption monitoring sensor
- System
- Aircraft crew life-support / oxygen equipment
- Associated Indicator
- IKZH-1
- Monitored Condition
- Presence of oxygen consumption according to existing product data
- Electrical Parameters
- Confirm from the DDC-1 passport
All specificationsCollapse specifications
- Rejected Legacy Data
- 230 V / 50 Hz motion-sensor specifications do not belong to this product
- Primary Designation
- DDC-1
- Original Cyrillic Designation
- ДДЦ-1
- Alternative Designations
- DDC-1; DDC1; DDC 1; ДДЦ-1; ДДЦ1; ДДЦ 1
- Manufacturer
- Not confirmed for the offered unit
- Aircraft / Equipment Application
- According to the exact aircraft, engine or equipment documentation stated above
- Installation Position
- Confirm from the illustrated parts catalogue and maintenance manual
- Connector / Pinout
- Confirm from the passport for the exact execution
- Interchangeability
- Not established by family name or external appearance
- Documentation
- Product passport and applicable installation / maintenance documentation
- Ordering Check
- Full marking, suffix, connector, required condition and documents
- Acceptance Control
- Compare marking, interfaces and test record with the approved requirement before installation
- Data Rule
- Unlisted values must be confirmed from the exact passport and not copied from another execution
- Related Products
- Same-category links are navigation only and do not state interchangeability
Payment & delivery
Orders ship from our hub in Dubai. Partner stock is first transferred to Dubai, then shipped to you.
Dubai stock: 100% before dispatch. Partner stock (Remote stock) and Pre-order: 50% advance payment to start the order and 50% before shipment from Dubai to you.
Availability, lead time, delivery cost and payment terms are confirmed for your order before payment.
Payment & delivery terms