TST-13
Thermoelectric Meter
Description
Retained product information
The thermoelectric thermometer TST-13-13 is designed for remote measurement of the temperature of the cylinder head. It consists of a temperature receiver, a pointer and connecting wires. The temperature receiver is a thermocouple, which is a junction of two dissimilar metals. The two ends are soldered together, placed under the candle, and represent the hot junction of the thermocouple. The other two ends remain cold and are connected to the pointer. The pointer is the device of the magnetic-electric system.
TST-13: purpose and identification
TST-13 is a Thermoelectric Thermometer that measures temperature with a thermocouple and compatible indicator. The exact execution is determined by the complete marking, series and documentation. A similar housing, common opening characters or a related function does not establish matching ratings.
This category contains different equipment classes: temperature receivers, thermometers, air- and liquid-pressure receivers, regulators and individual measurement units. The actual function of the item is therefore more important than the broad category name. Read the designation with every letter, digit, hyphen, version and series reference preserved.
Function in the measurement system
The item measures temperature with a thermocouple and compatible indicator. It is not necessarily a stand-alone indicator; depending on the design, it may operate with a remote indicator, regulator, pressure line or measurement set. The applicable documentation defines the circuit, medium, supply, range and connection arrangement.
For a temperature item, confirm the sensing principle, monitored medium, range and compatible indicator. For a pressure receiver, also confirm pressure type, channel count, ports, heating, drainage and connected lines. An RF measurement receiver must be selected by its own radio-frequency data rather than by requirements intended for an aircraft pressure or temperature sensor.
Selection by designation
Before ordering, compare the primary and alternative designations, execution, range, output, electrical supply, connector or ports, mounting, dimensions and mass whenever documented. Numerical values in Technical Details are retained from the previous card or a supporting source and must be checked against the passport for the actual unit.
Related modifications may differ in channel count, resistance, calibration, working medium, measurement limit, heater voltage or mounting interface. Do not treat them as interchangeable without an explicit documentary reference. General technical background is available under Thermoelectric Thermometer.
Pre-installation inspection
Incoming inspection includes checking the marking and documentation and examining the housing, sensing element, connector, pressure ports, drainage holes, mounting points and seals as applicable. Reject or investigate cracks, deformation, corrosion, contaminated passages and damaged contacts. Test the unit under the approved procedure for the exact execution.
After installation, check line tightness or electrical continuity, routing of pressure lines and wiring, and then perform the prescribed functional test. External integrity alone does not establish measurement accuracy. Assign an aircraft application only when supported by a passport, illustrated parts catalogue or maintenance document.
Related catalogue positions
Functionally related products include TNV-45K, TUE-8A, TNV-45, TUE-8M. They are grouped by measurement function for navigation and do not imply interchangeability. More items are listed in the Pressure & Temperature Sensors category.
Enquiry information
An enquiry for TST-13 should state the complete designation, quantity, required condition, marking photograph, delivery scope and required documents. When available, identify the associated indicator, regulator or system. Price, actual availability, condition, lead time and documentation are confirmed separately for the offered unit.
Technical details
Product Type: Thermoelectric Thermometer
Primary Designation: TST-13
Alternative Designations: TST-13; TST 13; ТСТ-13
Function: measures temperature with a thermocouple and compatible indicator
Selection Basis: Complete designation, execution, marking and passport for the specific item
Range and Signal: Only as stated in retained data and documentation for the exact execution
Interface: Confirm connector, ports, channel count, supply or heating before installation
Application: Only as supported by the passport, parts catalogue or approved installation documentation
Interchangeability: Not established by a similar index, housing or function
Inspection: Inspect marking, housing and interfaces; bench-test under the approved procedure
Documentation: Product passport and approved operating or repair documentation
Category: Pressure & Temperature Sensors
All specificationsCollapse specifications
Retained Technical Data:
1. Measurement range from -50 to 350 ° С.
2. Measurement error 4: 10 ° С.
3. Temperature conditions from 50 to – 60 ° С.
Payment & delivery
Orders ship from our hub in Dubai. Partner stock is first transferred to Dubai, then shipped to you.
Dubai stock: 100% before dispatch. Partner stock (Remote stock) and Pre-order: 50% advance payment to start the order and 50% before shipment from Dubai to you.
Availability, lead time, delivery cost and payment terms are confirmed for your order before payment.
Payment & delivery terms