AZZK-3 is an aircraft circuit breaker used in aircraft power-distribution and circuit-protection arrangements. The execution must be selected by more than current rating alone: the complete designation, network type, number of protected poles, control-member design, terminals and mounting interface all matter. Two breakers with a similar body or the same ampere value are not necessarily interchangeable because their trip curves and approved installation can differ.
The Latin search designation AZZK-3 corresponds to the original Cyrillic marking АЗЗК-3. Every suffix must remain in an inquiry. A suffix may distinguish sealing, illumination, control-handle configuration, number of circuits or another construction feature. Its exact meaning and applicability must be confirmed against the passport for the requested execution rather than inferred from appearance.
The primary operating role is thermal and electromagnetic releases with trip-free action. During normal operation current passes through the breaker contacts to the protected consumer. An unacceptable overload or fault causes the protective mechanism to open the circuit and isolate the affected feeder. Where the family uses trip-free action, restraining the control member in the ON position must not prevent an automatic trip.
The designation AZZK-3 identifies a 3 A execution. The family configuration is described as “Three-phase circuit breaker” for ac, line voltage up to 200 v, nominal frequency 400 hz. These are family-level identification data, not a substitute for the product passport. Voltage tolerances, time-current curve, breaking capacity and installation limits must be verified for the exact unit.
Aircraft circuit breakers are installed on breaker panels, distribution boards, feeder circuits and control lines supplying instruments, actuators, lighting and auxiliary equipment. The general architecture is described in the reference on aircraft electrical systems. The applicable aircraft or helicopter model is determined by the wiring diagram, illustrated parts catalogue, modification status and approved maintenance documentation for the individual airframe.
Related products in the same functional group include AZZK-2, AZZK-4, AZZK-5. They are presented for navigation and comparison only; they do not establish interchangeability. Adjacent current ratings have different settings, while suffixed versions may use different terminals, mounting geometry, sealing or cockpit-illumination execution.
A family name helps locate a product, but final selection is performed at complete-part-number level. Rated current must match the protected conductor and consumer, while the pole count must match the supply diagram. Current type, working voltage, AC frequency, time-current characteristic, climatic execution and sealing also require confirmation. When an inquiry provides only an abbreviated marking or a panel photograph, the breaker nameplate or the applicable illustrated-parts-catalogue position should be obtained before supply is approved.
Before installation, maintenance personnel should verify the nameplate, housing, terminals and mounting hardware and check for overheating, mechanical damage, contamination or corrosion. Electrical inspection follows approved documentation and may include contact resistance, insulation and trip-performance checks at specified current levels. Adjustment using data from a different rating is not acceptable. After installation, correct terminal torque and absence of abnormal heating under load must be confirmed.
An inquiry should state the complete AZZK-3 / АЗЗК-3 designation, rating, aircraft type, requested condition, quantity and passport requirement. More products are listed in the Circuit Breakers category. Supply is matched to the actual marking and documentation; condition, year, completeness and lead time must not be inferred from a photograph or a similar family name.
Product Type: Aircraft circuit breaker
Primary Designation: AZZK-3
Original Cyrillic Designation: АЗЗК-3
Alternative Designations: AZZK3; AZZK3
Family: AZZK
Execution Rating: 3 A
Configuration: Three-phase circuit breaker
Electrical Network: AC, line voltage up to 200 V, nominal frequency 400 Hz
Protection Function: Thermal and electromagnetic releases with trip-free action
Application: Aircraft and circuit defined by the parts catalogue and wiring diagram
Installation Area: Circuit-breaker panel, distribution board or feeder circuit as documented
Interchangeability: Only after verifying full designation, rating, trip characteristic and mounting
Documentation: Product passport, aircraft parts catalogue and maintenance manual
Family operating temperature: −60 to +60 °C
Execution rating: 3 A per phase
K suffix: control-member execution for red/white illumination; verify by passport
Category: Circuit Breakers
All shipments are carried out from our international warehouse in Dubai (UAE), as well as from our partners’ remote warehouses.
In Stock — items available in stock at the Dubai warehouse are dispatched within 5–10 business days after receiving 100% prepayment.
Remote Stock — items available at our partners’ remote warehouses are supplied within an average of 30–45 business days after receiving 100% prepayment.
Pre-Order — made-to-order products are manufactured and delivered within an average of 45–60 business days. Payment terms: 50% advance payment to start production, with the remaining 50% paid before dispatch from the Dubai warehouse after full readiness for shipment.
Returns & Changes (Restocking Fee)
For selected items, a RESTOCKING FEE of 10% may apply in case of return, order cancellation, or changes to the order specifications. This condition applies only to certain products and is confirmed at the order approval stage.
Warranty
All products are covered by a standard 6-month warranty.
Extended warranty is available upon request and is agreed individually; it may affect the final product price.
AZZK-3 is an aircraft circuit breaker used in aircraft power-distribution and circuit-protection arrangements. The execution must be selected by more than current rating alone: the complete designation, network type, number of protected poles, control-member design, terminals and mounting interface all matter. Two breakers with a similar body or the same ampere value are not necessarily interchangeable because their trip curves and approved installation can differ.
The Latin search designation AZZK-3 corresponds to the original Cyrillic marking АЗЗК-3. Every suffix must remain in an inquiry. A suffix may distinguish sealing, illumination, control-handle configuration, number of circuits or another construction feature. Its exact meaning and applicability must be confirmed against the passport for the requested execution rather than inferred from appearance.
The primary operating role is thermal and electromagnetic releases with trip-free action. During normal operation current passes through the breaker contacts to the protected consumer. An unacceptable overload or fault causes the protective mechanism to open the circuit and isolate the affected feeder. Where the family uses trip-free action, restraining the control member in the ON position must not prevent an automatic trip.
The designation AZZK-3 identifies a 3 A execution. The family configuration is described as “Three-phase circuit breaker” for ac, line voltage up to 200 v, nominal frequency 400 hz. These are family-level identification data, not a substitute for the product passport. Voltage tolerances, time-current curve, breaking capacity and installation limits must be verified for the exact unit.
Aircraft circuit breakers are installed on breaker panels, distribution boards, feeder circuits and control lines supplying instruments, actuators, lighting and auxiliary equipment. The general architecture is described in the reference on aircraft electrical systems. The applicable aircraft or helicopter model is determined by the wiring diagram, illustrated parts catalogue, modification status and approved maintenance documentation for the individual airframe.
Related products in the same functional group include AZZK-2, AZZK-4, AZZK-5. They are presented for navigation and comparison only; they do not establish interchangeability. Adjacent current ratings have different settings, while suffixed versions may use different terminals, mounting geometry, sealing or cockpit-illumination execution.
A family name helps locate a product, but final selection is performed at complete-part-number level. Rated current must match the protected conductor and consumer, while the pole count must match the supply diagram. Current type, working voltage, AC frequency, time-current characteristic, climatic execution and sealing also require confirmation. When an inquiry provides only an abbreviated marking or a panel photograph, the breaker nameplate or the applicable illustrated-parts-catalogue position should be obtained before supply is approved.
Before installation, maintenance personnel should verify the nameplate, housing, terminals and mounting hardware and check for overheating, mechanical damage, contamination or corrosion. Electrical inspection follows approved documentation and may include contact resistance, insulation and trip-performance checks at specified current levels. Adjustment using data from a different rating is not acceptable. After installation, correct terminal torque and absence of abnormal heating under load must be confirmed.
An inquiry should state the complete AZZK-3 / АЗЗК-3 designation, rating, aircraft type, requested condition, quantity and passport requirement. More products are listed in the Circuit Breakers category. Supply is matched to the actual marking and documentation; condition, year, completeness and lead time must not be inferred from a photograph or a similar family name.
Product Type: Aircraft circuit breaker
Primary Designation: AZZK-3
Original Cyrillic Designation: АЗЗК-3
Alternative Designations: AZZK3; AZZK3
Family: AZZK
Execution Rating: 3 A
Configuration: Three-phase circuit breaker
Electrical Network: AC, line voltage up to 200 V, nominal frequency 400 Hz
Protection Function: Thermal and electromagnetic releases with trip-free action
Application: Aircraft and circuit defined by the parts catalogue and wiring diagram
Installation Area: Circuit-breaker panel, distribution board or feeder circuit as documented
Interchangeability: Only after verifying full designation, rating, trip characteristic and mounting
Documentation: Product passport, aircraft parts catalogue and maintenance manual
Family operating temperature: −60 to +60 °C
Execution rating: 3 A per phase
K suffix: control-member execution for red/white illumination; verify by passport
Category: Circuit Breakers
All shipments are carried out from our international warehouse in Dubai (UAE), as well as from our partners’ remote warehouses.
In Stock — items available in stock at the Dubai warehouse are dispatched within 5–10 business days after receiving 100% prepayment.
Remote Stock — items available at our partners’ remote warehouses are supplied within an average of 30–45 business days after receiving 100% prepayment.
Pre-Order — made-to-order products are manufactured and delivered within an average of 45–60 business days. Payment terms: 50% advance payment to start production, with the remaining 50% paid before dispatch from the Dubai warehouse after full readiness for shipment.
Returns & Changes (Restocking Fee)
For selected items, a RESTOCKING FEE of 10% may apply in case of return, order cancellation, or changes to the order specifications. This condition applies only to certain products and is confirmed at the order approval stage.
Warranty
All products are covered by a standard 6-month warranty.